The Cyrix-Li-Charge will connect a battery charger with a 3 second delay:
if the load disconnect output of the VE.Bus BMS is high, and if it detects 13.7 V (resp.
27.4 V or 54.8 V) or more at its battery charger connection terminal, and if it detects 2 V or more at the battery terminal (the Cyrix will remain open if not connected to the battery).
The Cyrix-Li-Charge will deactivate immediately whenever its control input becomes free-floating, indicating cell over-voltage or cell over-temperature.
In general, a cell overvoltage alarm will reset shortly after charging stops.
The Cyrix will reconnect the charger after a 3 second delay.
After 2 attempts to reactivate with 3 seconds delay, the delay increases to 10 minutes.
Whenever the battery voltage is below 13.5 V (resp.
27 V or 54 V), the Cyrix will switch off with a delay of 1 hour.
Note 1:
In case of zero discharge current, or a small discharge current, the Cyrix will not disconnect shortly after the charger has been switched off and/or disconnected, because the battery voltage will still be higher than 13.5V.
Note 2:
If, after the Cyrix has been disconnected, the output of the battery charger immediately increases to 13.7 V or more, the Cyrix will reconnect with a 3 second delay.
if the load disconnect output of the VE.Bus BMS is high, and if it detects 13.7 V (resp.
27.4 V or 54.8 V) or more at its battery charger connection terminal, and if it detects 2 V or more at the battery terminal (the Cyrix will remain open if not connected to the battery).
The Cyrix-Li-Charge will deactivate immediately whenever its control input becomes free-floating, indicating cell over-voltage or cell over-temperature.
In general, a cell overvoltage alarm will reset shortly after charging stops.
The Cyrix will reconnect the charger after a 3 second delay.
After 2 attempts to reactivate with 3 seconds delay, the delay increases to 10 minutes.
Whenever the battery voltage is below 13.5 V (resp.
27 V or 54 V), the Cyrix will switch off with a delay of 1 hour.
Note 1:
In case of zero discharge current, or a small discharge current, the Cyrix will not disconnect shortly after the charger has been switched off and/or disconnected, because the battery voltage will still be higher than 13.5V.
Note 2:
If, after the Cyrix has been disconnected, the output of the battery charger immediately increases to 13.7 V or more, the Cyrix will reconnect with a 3 second delay.